10kV/2800kW Coal Mine Hoist Inverter
The module is a flexible, modular power quality product designed for harmonic suppression, power factor correction, and three-phase balance.
Rated capacity: 30A/50A/75A/100A/150A/200A
Rated input: 200/400/480/690/800V AC
Grid frequency: 50/60 Hz ± 10%
Filter range: 2 to 50 orders
Installation types: wall-mounted, rack-mounted, upright
Power grid configuration: 3P3W, 3P4W
Service Hotline: +86-10-81799630
Email: Liry_chinnovo@126.com
Category:
Special frequency converter
Keywords:
Product Description
Product Overview
Input 10 kV , output 6 kV Rated power 2800 kW Rated output current 320A Power units are connected in series, with vector control. Four-quadrant operation , Zero-speed full torque Hover, Energy feedback 35%+ Save electricity ;
Principle Topology
Technical Specifications
Parameter |
|
Product Model |
CN710-281-10/6-413 |
Rated capacity |
2800 kW |
Rated input voltage |
10 kV (±10%), 3-phase, 50 Hz (±5%) |
Rated output voltage |
0 ~ 6 kV (varies linearly with output frequency) |
Rated output current |
≈ 309 A |
Topological structure |
Power unit series multilevel technology |
Work Quadrant |
Four quadrants (Energy can flow in both directions and features full regenerative braking capability) |
Cooling method |
Forced air cooling (indoor air-cooling), standard equipped with a centrifugal fan. |
Protection level |
IP21 (Standard) |
Performance metrics |
|
Input power factor |
≥ 0.96 (at rated load, the power factor is >0.95 across the 20% to 100% load range) |
Overall machine efficiency |
≥ 97% (rated load, excluding transformer) |
Overload capacity |
120% rated current – 1 minute; 150% rated current – 2 seconds |
Speed control range |
0 ~ 120% rated speed |
Speed control accuracy |
±0.1% (closed-loop encoder feedback) |
Speed ratio |
0.111111111 |
| Total Harmonic Distortion (THD) | Input current THD: < 4% (at rated load) |
Output Voltage THD: < 3% (no output filter required) |
|
Braking performance |
Built-in regenerative energy feedback unit, 100% of rated power energy is fed back to the grid. |
System Composition |
|
Phase-shifting transformer |
Dry-type, Class H insulation, 10 kV primary side, multiple phase-shifting windings on the secondary side, designed to eliminate harmonics. |
Power unit |
Quantity: 5 units in series per phase, totaling 15 units. |
Rated power: Approximately 117 kW per unit |
|
Topology: H-bridge IGBT PWM inverter circuit |
|
Control: Fiber-optic driven, fully electrically isolated |
|
Control system |
Multi-stage DSP + FPGA all-digital control system, employing carrier phase-shifting technology. |
Human-Machine Interface HMI |
Touchscreen with Chinese/English display, used for parameter setting, status monitoring, fault recording, and query. |
Switchgear |
Optional built-in or external high-voltage input circuit breakers and disconnect switches. |
Protection function |
|
System Protection |
Input overvoltage/undervoltage, overcurrent, phase loss, phase imbalance, and transformer overheating. |
Power unit protection |
Overvoltage, undervoltage, overcurrent, IGBT overheating, and fiber-optic communication failure in the unit. |
Motor protection |
Overload, short circuit, locked rotor, overspeed |
Other |
Control system self-diagnosis, fast-blow fuse failure |
External dimensions (optional): Approximately 3800 mm × 1500 mm × 2400 mm
Product Features
- Power unit The rectifier side adopts AFE Active front-end technology, bidirectional power flow
- Under downshift conditions, regenerated electrical energy is automatically fed back into the power grid, achieving an energy-saving rate exceeding... 35%
- Zero Quick 150% Rated torque output, heavy-load hovering without jitter.
- Torque response time <5ms, Prevent “ Slip hook ”
- Low speed 0.1 Hz~ 18.6 Hertz Run
- Intelligent Interlocked Control for Mechanical Brakes (Release Detection) → Torque establishment)
- Real-time Fault Diagnosis: Overvoltage / Undervoltage, overspeed, and encoder failure redundancy
Application scenarios
Current Pain Points and Solutions in the Industry Related to This Product |
|
Traditional lift system issues |
Qi'an Four-Quadrant Inverter Solution |
⚠️ Insufficient starting torque under heavy load, risk of vehicle rollback.
|
✅ 200% starting torque Zero-speed hover anti-slip hook
|
⚠️ Brake pads wear out quickly, resulting in high maintenance costs.
|
✅ Energy feedback to the power grid Reduce mechanical braking
|
⚠️ Energy waste and low energy efficiency during distribution.
|
✅ Efficiency of feedback > 97% , 30%+ energy savings
|
⚠️ Speed regulation is not smooth, and positioning accuracy is poor.
|
✅ Millimeter-level closed-loop control S-curve acceleration and deceleration
|
Energy-saving speed regulation and control for heavy-duty equipment such as pumps, fans, and compressors used in industries including mining, metallurgy, power generation, petrochemicals, and water conservancy. ;
Mine shaft Drilling a well Elevator : Suitable for multi-rope friction type / Single-rope winding hoist
Application site photos
Figure 1 On-site images of the high-voltage inverter
Figure 2 Elevator
Figure 3 Elevator Control Room
Figure 4: Power unit AFE Waveform
Figure 5: Output current waveform of the inverter and voltage waveform of the unit busbar
Next one
Get a quote
If you’re interested in our products, please leave your email address, and we’ll get in touch with you as soon as possible. Thank you!
Beijing Qian'an Electrical Technology Co., Ltd.
Service Hotline: +86-10-81799630
Email: Liry_chinnovo@126.com
Address: Room 906-907, Unit 3, Building 3, No. 42, North Seventh Road, Changping District, Beijing市
Copyright © Beijing Qian Electric Technology Co., Ltd.
E-mail:
Telephone:
在线客服添加返回顶部
右侧在线客服样式 1,2,3 4
图片alt标题设置: Beijing Qian'an Electrical Technology Co., Ltd.
表单验证提示文本: Content cannot be empty!
循环体没有内容时: Sorry, no matching items found.
CSS / JS 文件放置地