  • 900V1000kW三合一特种控制器-1.jpg
  • 900V1000kW三合一特种控制器-2.jpg
  • 900V1000kW三合一特种控制器-3.jpg

900V 1000kW High-Power, High-Density Water-Cooled Controller

The module is a flexible, modular power quality product designed for harmonic suppression, power factor correction, and three-phase balance.

Rated capacity: 30A/50A/75A/100A/150A/200A
Rated input: 200/400/480/690/800V AC
Grid frequency: 50/60 Hz ± 10%
Filter range: 2 to 50 orders
Installation types: wall-mounted, rack-mounted, upright
Power grid configuration: 3P3W, 3P4W

Service Hotline: +86-10-81799630

Email: Liry_chinnovo@126.com

Category:

Special controller

Keywords:

Product Description

Product Overview

This composite drive system controller includes two 400-kW motor controllers (A and B), a 1,000-kW motor controller (C), and a 14-kW permanent-magnet oil pump motor controller. It is designed to control various composite motors and features high power and high-voltage capabilities.

Rated power: 1000kW
Input voltage range: 900VDC
Rated output current: 485A

 

Control Strategy Block Diagram

 

Technical Specifications

Name Function or performance description Note
Integrated Controller Input Characteristics Module Composition Drive motor MCU1 module, drive motor MCU2 module, oil pump motor module, DC-AC module,  
DC input voltage range 650 VDC (undervoltage point) to 1050 VDC (overvoltage point), rated at 900 VDC. Linear derating below 900 VDC.  
Controller auxiliary power 28V System: Rated Voltage: 18–36 VDC; Maximum Current: 5 A  
Drive motor controller Motor 1
Output characteristics
Rated/Peak Output Power Rated: 400kW Peak: 600kW  
Output voltage 0~Input voltage × 0.707, Maximum: 636 VAC  
Rated/Peak Output Current Rated: 750A Peak: 1085A (300S)  
Overload capacity 160% of rated current for 60 seconds, with a 10-minute interval. Inverse-time characteristic
Output frequency range 0.00-900.00Hz  
Motor 2
Output characteristics
Rated/Peak Output Capacity Rated: 400kW Peak: 600kW  
Output voltage 0~Input voltage × 0.707, maximum: 636V  
Rated/Peak Output Current Rated: 750A Peak: 1085A (300S)  
Overload capacity 160% of rated current for 60 seconds, with a 10-minute interval. Inverse-time characteristic
Output frequency range 0.00-900.00Hz  
Electrical performance
Control function
Control method VC (vector)  
Communication method CAN2.0B  
Frequency setting method CAN message  
Maximum efficiency of the controller 98%  
Speed control accuracy ≤±1% @ steady state Closed-loop vector control
Torque response ≤300ms @ 10%~90% Tn Closed-loop vector control
Torque precision control ≤±5% @ steady state Closed-loop vector control
Protection function Provides a variety of fault protection functions: overcurrent, overvoltage, undervoltage, overtemperature, output phase failure, overload, short circuit, and power limit protection.
Input overvoltage protection 1050VDC  
Input undervoltage protection 650VDC  
Controller overload protection Parameter Settings Inverse-time characteristic
Output phase-loss protection When a phase loss is detected, phase-loss protection is activated.  
Output short-circuit protection Short-circuit protection when an output short circuit is detected.  
Motor Overtemperature Protection Set alarm and protection values via software.  
Oil pump motor controller Output characteristics Rated/Peak Output Power 14kW/21kW  
Output Voltage (V) 0~Input voltage × 0.707, maximum: 636V  
Rated/Peak Output Current 15.4A/23.1A (180s)  
Overload capacity 150% rated current for 60 seconds, 180% rated current for 10 seconds, 200% rated current for 1 second. Inverse-time characteristic
Output frequency range 0.00-600.00Hz  
Maximum efficiency of the controller ≥97%  
Electrical performance
Control function
Control method VC (vector)  
Communication method CAN2.0B  
Frequency setting method CAN message  
Speed control accuracy ≤±1% @ steady state Open-loop vector control
Protection function Input reverse connection protection Plug-in anti-misinsertion  
Input overvoltage protection Parameter Settings  
Input undervoltage protection Parameter Settings  
Controller overload protection Parameter Settings  
Overcurrent protection Software overcurrent parameter setting; hardware overcurrent 2.0 × In  
Overtemperature protection for the controller Parameter Settings  
Output phase-loss protection Phase-loss protection when phase loss is detected.  
Output short-circuit protection Short-circuit protection when an output short circuit is detected.  
Motor Overtemperature Protection Set alarm and protection values in the software.  
Generator controller Output characteristics Rated/Peak Output Power 1000kW/1320kW  
Output Voltage (V) 900VDC  
Rated/Peak Output Current 485A/630A  
Overload capacity 160% of rated current for 60 seconds, with a 10-minute interval.  
Output frequency range 0.00–700.00 Hz  
Electrical performance
Control function
Control method VC (vector)  
Communication method CAN2.0B  
Frequency setting method CAN message  
Speed control accuracy ≤±1% @ steady state  
Maximum efficiency of the controller 98%  
Protection function Input reverse connection protection Plug-in anti-misinsertion  
Input overvoltage protection Parameter Settings  
Input undervoltage protection Parameter Settings  
Controller overload protection Parameter Settings  
Overcurrent protection Software overcurrent parameter setting; hardware overcurrent 2.0 × In  
Overtemperature protection for the controller Parameter Settings  
Output phase-loss protection Phase-loss protection when phase loss is detected.  
Output short-circuit protection Short-circuit protection when an output short circuit is detected.  
Motor Overtemperature Protection Set alarm and protection values in the software.  
Protection rating IP67  

 

External dimensions (optional)

 

Product Features

  • High electromagnetic compatibility performance
  • Controls multiple motors, high voltage, high power
  • Supports multiple communication protocols (CAN, RS485, ModBus)

 

Application scenarios

Special-purpose motor controller

 

Get a quote

If you’re interested in our products, please leave your email address, and we’ll get in touch with you as soon as possible. Thank you!

中企跨境-全域组件 1.97 制作前进入CSS配置样式

E-mail:

Telephone:

在线客服添加返回顶部

右侧在线客服样式 1,2,3 4

图片alt标题设置: Beijing Qian'an Electrical Technology Co., Ltd.

表单验证提示文本: Content cannot be empty!

循环体没有内容时: Sorry, no matching items found.

CSS / JS 文件放置地